Click below link to swith to our other product categories |
|
|
|
|
|
|
Tunable Filter
1. Basal Description
|
The tunable filter is a late-model RF Band Pass Filter. It has "Reduce Transmitter Noise" " Improve Receiver Sensitivity" " Improve Cosite Performance" advantages etc..
|
2. Environmental Parameter
Environmental Parameter |
Standard |
Especial |
Vibration(5-2000Hz) |
10g |
20g |
Shock(11ms) |
30g |
50g |
Relative Humidity |
0~90% |
95% |
Operating Temperature |
-40 ~ +60°C |
-55 ~ +85 °C |
Storage Temperature |
-40 ~ +100°C |
-40 ~ +125°C |
Package |
Surface Mount, SMA and customization available |
3. Tunable Filter(Four Series)
|
Low Power Voltage Tuning Filter Series |
|
|
|
Tunable Frequency Range: |
30 to 610MHz |
|
|
|
Sub-band: |
30~90MHz,30~120MHz, 108~174MHz, 225~400MHz, 225~512MHz, 215~610MHz,200~450MHz
Customization available |
|
|
Power Handling: |
+5dBm ~ +8dBm max |
|
|
Tuning Voltage: |
+0.5 ~ +28V DC |
|
|
Frequency Drift: |
+/-1MHz max(-40 ~ +60°C) |
|
|
1. Front End Preselection Voltage Tuning Filter |
|
|
|
3dB Bandwidth: |
10%~40% |
|
|
|
Shape Factor(30dB BW/3dB BW): |
6 max(two sections) |
|
|
|
Power Handling: |
+5dBm ~ +8dBm |
|
|
|
Insertion Loss in Pass Band: |
3dB max |
|
|
|
Tuning Time: |
10us max |
|
|
|
Input and Output Impedance: |
50Ohms |
|
|
|
VSWR: |
2.0 max |
|
|
|
Group Delay: |
150ns max |
|
|
|
Group Delay Ripple: |
30ns max |
|
|
|
Phase-Frequency Characteristic: |
Linear in 3dB bandwidth |
|
|
|
Phase Ripple: |
+/-5° |
|
|
|
Survival Input Power: |
1W |
|
|
2. Postposition Preselection Voltage Tuning Filter |
|
|
|
3dB Bandwidth: |
4%~10% |
|
|
|
Shape Factor(30dB BW/3dB BW): |
A Type: 4 max(four sections)
B Type: 3 max(six sections)
C Type: 2 max(eight sections) |
|
|
|
Power Handling: |
+5dBm ~ +8dBm |
|
|
|
Insertion Loss in Pass Band: |
A Type: 6dB max,B Type: 8dB max,C Type:10dB max |
|
|
|
Tuning Time: |
10us max |
|
|
|
Input and Output Impedance: |
50Ohms |
|
|
|
VSWR: |
2.0 max |
|
|
|
Group Delay: |
150ns max |
|
|
|
Group Delay Ripple: |
30ns max |
|
|
|
Phase-Frequency Characteristic: |
Linear in 3dB bandwidth |
|
|
|
Phase Ripple: |
+/-5° |
|
|
3. Combined Voltage Tuning Filter |
|
|
|
|
|
|
|
|
|
|
1W Medium Power Digital Control Frequency Hopping Filter Series |
|
|
Power Handling: |
+30dBm |
|
|
Hopping Speed: |
20us max |
|
|
Hopping Point: |
250(Customization available) |
|
|
Frequency Range: |
30 to 610MHz |
|
|
Sub-band: |
30~90MHz,30~120MHz, 108~174MHz, 225~400MHz, 225~512MHz, 215~610MHz,200~450MHz
Customization available |
|
|
Input and Output Impedance: |
50Ohms |
|
|
Frequency Drift: |
+/-0.5MHz max(-40 ~ +60°C) |
|
|
Power Supply: |
+5V, +28V,...(+100V) |
|
|
Digital Control Protocol: |
8 bit Parallel(TTL Compatible) |
|
|
Tune Adress: The binary tuning word is determined by the following relationship: |
|
|
|
|
|
For example: If you wish to tune to 300 MHz using a 225 to 400 MHz filter, the tune word is: (300-225)/(400-225)x250=107.14(01101011 binary)
NOTE: Round off to the nearest decimal integer!
|
|
|
1. Front End Preselection Frequency Hopping Filter |
|
|
|
3dB Bandwidth: |
10%~40% |
|
|
|
Shape Factor(30dB BW/3dB BW): |
6 max(two sections) |
|
|
|
Insertion Loss in Pass Band: |
6dB max |
|
|
|
VSWR: |
2.0 max |
|
|
|
Group Delay: |
150ns max |
|
|
|
Group Delay Ripple: |
30ns max |
|
|
|
Phase-Frequency Characteristic: |
Linear in 3dB bandwidth |
|
|
|
Phase Ripple: |
+/-5° |
|
|
2. Postposition Preselection Digital Control Frequency Hopping Filter |
|
|
|
3dB Bandwidth: |
4%~10% |
|
|
|
Shape Factor(30dB BW/3dB BW): |
A Type: 6 max(four sections)
B Type: 4 max(six sections) |
|
|
|
Insertion Loss in Pass Band: |
A Type: 6dB max,B Type: 7dB max |
|
|
|
VSWR: |
2.0 max |
|
|
|
Group Delay: |
150ns max |
|
|
|
Group Delay Ripple: |
30ns max |
|
|
|
Phase-Frequency Characteristic: |
Linear in 3dB bandwidth |
|
|
|
Phase Ripple: |
+/-5° |
|
|
3. Combined Digital Control Frequency Hopping Filter |
|
|
|
|
|
|
|
|
|
|
50W High Power Pass Band Switching Filter Bank Series |
|
|
|
|
|
Technical Specification: |
|
|
Frequency Range: |
30 to 610MHz |
|
|
Sub-band: |
30~90MHz,30~120MHz, 108~174MHz, 225~400MHz, 225~512MHz, 215~610MHz,200~450MHz
Customization available |
|
|
|
Each section can be divided severval sub-band according to 5~50% 1dB bandwidth |
|
|
Max Input power: |
150W min |
|
|
Insertion Loss in Pass Band:
(Including the Insertion Loss of PIN Switch ) |
BW/f0≥5%: 2dB max |
BW/f0≥10%: 1.8dB max |
|
|
BW/f0≥20%: 1.5dB max |
BW/f0≥40%: 1.2dB max |
|
|
Attenuation: |
BW/f0≥5%: -65dB max |
BW/f0≥10%: -60dB max |
|
|
|
BW/f0≥20%: -50dB max |
BW/f0≥40%: -50dB max |
|
|
Input and Output Impedance: |
50 Ohms |
|
|
|
VSWR: |
2.0 max |
|
|
|
Power Supply: |
+5V, |
+10V, |
+100V |
|
|
|
Frequency Switching Time: |
20us max |
|
|
|
|
Combined Digital High Power Frequency Hopping Filter |
|
|
|
|
|
Technical Specification: |
|
|
Frequency Range: |
30 to 610MHz |
|
|
Sub-band: |
30~90MHz,30~120MHz, 108~174MHz, 225~400MHz, 225~512MHz, 215~610MHz,200~450MHz
Customization available |
|
|
Max Input power: |
150W min |
|
|
Input and Output Impedance: |
50 Ohms |
|
|
VSWR: |
2.0 max |
|
|
Power Supply: |
+5V, +28V,+100V |
|
|
Hopping Speed: |
25us max |
|
|
Digital Control Protocol: |
8 bit Parallel(TTL Compatible) |
|
|
Tuning Adress: |
Same AS 1W Mediun Power Digital Control Frequency Hopping Filter |
|
|
Tunable filter size can be customized |
|
|